Aerated concrete reinforcement. The rules, which everyone wants to alter under itself.
Samostroyschiki still those people.When the rules are not in their interests, trying to come up with something of their own, and still others argue that this should be done!π
βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ βͺ
I'm also building a house with his own handsAnd also I bring their creative ideas in the building process. But I do it insignificant and irresponsible things. And the rest rely on the rules, or at least the opinions of influential people who have practical experience.
In matters related to concrete, for me, basically, that person became President of the Association of aerated concrete in Russia Gleb GreenfeldWho knows of aerated concrete, if not all, the more likely some "specialists". Therefore, all the decisions I have been relying on his opinion.
πΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉπΉ
In his article "Wrong when reinforced aerated concrete. About how little things affect the entire outcome."I wrote about what I encountered when reinforced aerated concrete masonry. And in many of the comments
"Experts" began to assertThat I was doing wrong, and that the reinforcement does not have to.It's time to find out.
Why 1οΈβ£ reinforced?
Perhaps most importantly, what all think. And of course there are many examples of unreinforced masonry, which is all right.
β But how many examples of cracked wall because of the shrinkage (rather than a weak foundation), which also had no reinforcement. And all at once throw off the fact that aerated concrete - it's the bad stuff.
And the fact that you decided that reinforcement for fools - it is generally not affected.
β reinforcement in the masonry does not hold the walls of the gap, and It does not work in the concrete.It serves to prevent shrinkage cracksUntil such time as gas concrete settles and dries.
2οΈβ£ Grid reinforcement instead.
It is theoretically possible, and the net, I know that just put perfopolosy instead of valves. But it will increase the thickness of the seam between the blocks, Which is also undesirable. A fixture hidden in Stroebe, does it not affected.
Just blocks manufacturers themselves are advised to use in its recommendations it is fitting.
3οΈβ£ All invented to pull the money.
This is the first that shout all fans of a freebie. So, in my opinion, the construction - it's not the best place for savings. But of course throwing money too, not everyone can afford.
β But in matters of the walls, as well as in the construction of the foundation, it is better to be safe than... You know yourself.
And to be honest, I can not understand how the aerated concrete manufacturers recommending reinforcement associated with the production of fittings, which they need to stick everywhere?
Well, although anything can happen...
Therefore, ignore the reinforcement in my house, I did not.
β I am choosing, between inexpensively and possible cracks, I choose the first.
And I risk deleting simple reinforcement of the process, not desirable.
Therefore, all who believe that all is not well thought otherwiseI can only wish good luck. And for people who still have doubtsI would like to advise to listen to the opinions of people who know, really experts in their field. Although here, too, need to look to find ...
π₯ We subscribe to CANAL π₯ and putπ.