Additional area without construction: the transformation of the cold attic into a comfortable loft
Examples of alterations cold attic floor in mansard roofs and building warm
As an extension, loft can be laid in the project initially, or to build on in the future, if the need arises. Fortunately, lightweight frame structures compatible with virtually any base, even well "pozhivshimi". But unlike the annexes, to obtain additional, albeit a small area, it is possible and without major reconstruction - insulate cold attic. The mass of options, as well as ways to implement and everything, see what turn the attic of our craftsmen.
Content
- Penthouses from Navigator6989
- Warming of the old gable roof for seasonal residence: it was-was
- Photo report on the device of warm mansard roof
- Seasonal loft with mezzanine
Penthouses from Navigator6989
Navigator6989
Member FORUMHOUSE
The gable roof, as it were embedded insulated attic. For interior trim and insulation consider such a structure:
- existing rafters;
- bolt;
- inclined beam for attachment of insulation and interior trim, 100x50 mm increments insulation;
- Front 80h40 mm, for mounting interior trim;
- Front 80h40 mm, for securing insulation from the outside;
- cantrail 90h40 mm;
- waistrail 200h40 mm;
- beam 100x50 mm.
Since as a heater in the vertical walls formed plating, ecowool (200 mm), inner and outer racks are staggered for more uniform heat-insulating layer.
Frame, metal boxes for electrical wiring.
Ramps under mineral wool insulation roll (200 mm) with overlap joints, the ends turned nearly 300 mm.
at the same time Navigator6989 She arranged through the attic air supply for ventilation of the first floor.
Outside view.
Interior decoration:
- It paneling - an imitation of timber;
- ceiling - stretched canvas;
- floor - decking (27 mm) on logs (step 450 mm), with the fixation screws in spike angle 45⁰, with subsequent grinding. Finish multilayered: white glaze in two layers and three layers of alkyd-urethane varnish for decoration.
Warming of the old gable roof for seasonal residence: it was-was
patriotlyakh
Member FORUMHOUSE
Roof, 4 × 6 m, the height 2.6 m approximately, eighties classic: rafters 100 × 110 mm, with a pitch of 1 m, from twenty lathing, roofing slate. Willing to warm attic: slate roofing felt, sheathing, insulation between rafters (possibly with lace 2-3 cm from the wall furring) on the stapler steam to the rafters, Hem lining directly on the joists.
Approximate pie.
It was.
patriotlyakh
Here's what happened as a result, if you are interested, check.P.S. Two new year greeted boiler biggest comprised 30-40%. Normal flight.
In the process.
It was.
Photo report on the device of warm mansard roof
Igor3004
Member FORUMHOUSE
I keep a photo report on the construction of their houses from profiled bars. Building year is over, spread the results of stage device warm roof. Insulation - rockwool (two layers 150 mm); base - OSB; topcoat - two-layer soft tile.
Removing the temporary roof trusses and alignment.
Vapor barrier with sizing joints, crate.
Outside view.
Installing drip condensation outlet.
Laying insulation, membranes, crate.
Laying kontrbrusa, lathing, the base under the soft tile (GSP-3, 12 mm).
Fastening for gutters, protective mesh (to the extreme number of stacking plates).
The roof is ready for installation of carpet underlay.
Drip edge, fascia board, wind braces.
Carpet underlayment, the starting strip (reassurance of ordinary shingles), shingles, snow stop.
A device for lifting the shingles on the roof.
Conclusion ventilation through the roof:
- fanovy riser;
- extract from the toilet;
- extractor fan from the kitchen;
- an extract from the boiler room.
Fascia board, water drainage system, hemming overhangs.
Implementation of the second ramp similar to the first.
The penetration of the chimney of the fireplace.
Ridge aerator for ventilation of roof space.
Finished roof.
Inner space.
Seasonal loft with mezzanine
viktor50
Member FORUMHOUSE
The house is built and finished himself - attic room less insulated, designed for bedrooms for the summer period. For permanent naturally need more insulation. I have made in the wall of the mezzanine and is now well come to the rescue, to feature, you can push, and so would have to do special exercises or additional cabinets. Anyway, somewhere you need to put until the desired toys and other trifles. Photo of two attic rooms under construction - those of 16 m², two more of 12 m², at the bottom underneath the first floor, 20 m² room.
Output
If necessary, the attic can be converted and cold attic, built at the "days of yore" when on the membranes and insulation rays were not thought of. And if it was originally laid in the project, do not have to reinvent the "wheel", to comply with the technology enough.
For more information about insulation of attics and proper roofing pie - in profile on a branch forum. And to simplify the constructive, can be used diffusion membrane. In the video - how to repair a problematic roof attic classical and simplistic.
Subscribe to the channel! Share on social networks! Join the community FORUMHOUSE!