I've used that many are skeptical about the decisions I make on his construction site.

First, in the comments to my articles, I wrote that my foundation will crack, then, that the aerated concrete is destroyed, then it filled up the fence, and so on. N...

And one of the last articles (Problems of long span in the hardwood floor. I decide the matter without unnecessary costs.) I gained a lot of views. It tells about my hardwood floor.And many readers have written in the comments that I piled complete nonsense, and in general, it is dangerous to walk.

And it made me think seriously:

  • Whether my publications read by people who do not understand anything at all in the building?
  • Or is it so bad I explained?

Relying on the second embodimentIt is most likely my fault and was told few details, today I scientifically, logically and practically explain its decision.

A little background:

And so, we have the room 5 for 4 (plus, minus). In it I had to do a hardwood floor. Beams need to be put along the 5 meters to connect to the rafters. And I decided to do so:
instagram viewer
Those. I have not used pillared beamAnd I divide the span into two parts, and in the middle, across, threw a reinforced beam, and have it put minor.

And that's why everything will be fine!

My 1️⃣ reinforced beam, which carries most of the load in the center of the overlap, firmly anchored at three points.

💥 at the ends - on the wall and on the bay.

💥And in the middle, I plan to put the column 150 of the timber 150.

To make it clear exactly)))
To make it clear exactly)))
It turns out, this beam will be very tough, and perform role, in practice, baffles.

2️⃣ turns span of 5 meters, is divided into two parts Secondary beams that come from the walls have a length of 2.5 meters and even by simple table which can be found on the Internet boards 50 to 200, with step 600 mm (as it made me), quite enough.

3️⃣ Then just practice. When I stand in the center of the overlap (where my many "experts" even forbidden to go), And jump is a slight vibration. But despite the fact that the column is still not worth it. And when the center will back safely, then everything will be more than enough.

4️⃣ And with all this, I do not spend huge beam sections and spliced ​​boards in multiple layers.

In fact the additional costs are only two boards 50 to 200, bar 150 to 150, and brackets to connect the entire structure. And as for the ease of installation, as I generally keep quiet compared to the giant beams.

As a result, it was not an attempt to someone to prove somethingAnd the call does not throw words to waste. There is a normal explanation, I always listened. A hot air at the level of: "What is this g... but?" or "All you need to bear!" - this is... About anything.

And as such design has allowed me to do almost no waste, all the overlap, I'll discuss in the next article.

Therefore put Like 👍 andSUBSCRIBE TO CHANNEL, not to miss.

The saleswoman from "Pyaterochka" told a trick how you can buy cheaper products and save money.

The saleswoman from "Pyaterochka" told a trick how you can buy cheaper products and save money.

Good afternoon, dear readers! In our current economic situation, many are interested in the quest...

Read More

A way to lay tiles without crosses: a beginner can do it too

Anyone who, at least once in his life, laid tiles in the toilet, bathroom or kitchen on his own, ...

Read More

Why are lifting gates always better than swing gates?

This year I put up a part of the fence on the side of the road and got close to the gate. And the...

Read More

Instagram story viewer